EasyManua.ls Logo

YASKAWA CR700

YASKAWA CR700
886 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter List
10
10.19 Parameters Changed by E1-03 [V/f Pattern Selection]
YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual 555
10.19 Parameters Changed by E1-03 [V/f Pattern Selection]
The default settings of the parameters listed in the following table vary depending on the setting of A1-02
[Control Method Selection] and E1-03 [V/f Pattern Selection].
Table 10.1 Parameters Changed by E1-03 (2003 to 2018 and 4002 to 4009)
No.
Unit
Setting Value
Control
Method (A1-
02 Setting)
E1-03 0 1 2 3 4 5 6 7 8 9 A B C D E F
OLV
(2)
CLV
(3)
E1-04 Hz 50.0 60.0 60.0 72.0 50.0 50.0 60.0 60.0 50.0 50.0 60.0 60.0 90.0 120.0 180.0
50.0
*1
50.0 50.0
E1-05
*2
V 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
200.0
*1
200.0 200.0
E1-06 Hz 50.0 60.0 50.0 60.0 50.0 50.0 60.0 60.0 50.0 50.0 60.0 60.0 60.0 60.0 60.0
50.0
*1
50.0 50.0
E1-07 Hz 2.5 3.0 3.0 3.0 25.0 25.0 30.0 30.0 2.5 2.5 3.0 3.0 3.0 3.0 3.0 2.5
*1
3.0 -
E1-08
*2
V 15.0 15.0 15.0 15.0 35.0 50.0 35.0 50.0 19.0 24.0 19.0 24.0 15.0 15.0 15.0
15.0
*1
14.4 -
E1-09 Hz 1.3 1.5 1.5 1.5 1.3 1.3 1.5 1.5 1.3 1.3 1.5 1.5 1.5 1.5 1.5 1.3
*1
0.5 0.0
E1-10
*2
V 9.0 9.0 9.0 9.0 8.0 9.0 8.0 9.0 11.0 13.0 11.0 15.0 9.0 9.0 9.0 9.0
*1
3.0 -
E1-11 Hz 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
*1
0.0 0.0
E1-12
*2
V 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
*1
0.0 0.0
E1-13
*2
V 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
*1
0.0 0.0
E1-14
*2
V 15.0 15.0 15.0 15.0 35.0 50.0 35.0 50.0 19.0 24.0 19.0 24.0 15.0 15.0 15.0
15.0
*1
14.4 -
E1-15
*2
V 9.0 9.0 9.0 9.0 8.0 9.0 8.0 9.0 11.0 13.0 11.0 15.0 9.0 9.0 9.0 9.0
*1
3.0 -
E1-16
*2
V 15.0 15.0 15.0 15.0 35.0 50.0 35.0 50.0 19.0 24.0 19.0 24.0 15.0 15.0 15.0
15.0
*1
14.4 -
E1-17
*2
V 9.0 9.0 9.0 9.0 8.0 9.0 8.0 9.0 11.0 13.0 11.0 15.0 9.0 9.0 9.0 9.0
*1
3.0 -
E1-18
*2
V 15.0 15.0 15.0 15.0 35.0 50.0 35.0 50.0 19.0 24.0 19.0 24.0 15.0 15.0 15.0
15.0
*1
14.4 -
E1-19
*2
V 9.0 9.0 9.0 9.0 8.0 9.0 8.0 9.0 11.0 13.0 11.0 15.0 9.0 9.0 9.0 9.0
*1
3.0 -
*1 Default settings for E1-04 to E1-10, E3-04 to E3-10 [V/f Pattern for Motor 2], and E7-04 to E7-10 [V/f Pattern for Motor 3]. These
settings are the same as those for the V/f pattern when E1-03 = 0 [Const Trq, 50Hz base, 50Hz max].
*2 This is the value for 200 V class drives. Double the value for 400 V class drives.
Table 10.2 Parameters Changed by E1-03 (2025 to 2180 and 4015 to 4091)
No.
Unit
Setting Value
Control
Method (A1-
02 Setting)
E1-03 0 1 2 3 4 5 6 7 8 9 A B C D E F
OLV
(2)
CLV
(3)
E1-04 Hz 50.0 60.0 60.0 72.0 50.0 50.0 60.0 60.0 50.0 50.0 60.0 60.0 90.0 120.0 180.0
50.0
*1
50.0 50.0
E1-05
*2
V 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
200.0
*1
200.0 200.0
E1-06 Hz 50.0 60.0 50.0 60.0 50.0 50.0 60.0 60.0 50.0 50.0 60.0 60.0 60.0 60.0 60.0
50.0
*1
50.0 50.0
E1-07 Hz 2.5 3.0 3.0 3.0 25.0 25.0 30.0 30.0 2.5 2.5 3.0 3.0 3.0 3.0 3.0 2.5
*1
3.0 -
E1-08
*2
V 14.0 14.0 14.0 14.0 35.0 50.0 35.0 50.0 18.0 23.0 18.0 23.0 14.0 14.0 14.0
14.0
*1
13.2 -
E1-09 Hz 1.3 1.5 1.5 1.5 1.3 1.3 1.5 1.5 1.3 1.3 1.5 1.5 1.5 1.5 1.5 1.3
*1
0.5 0.0
E1-10
*2
V 7.0 7.0 7.0 7.0 6.0 7.0 6.0 7.0 9.0 11.0 9.0 13.0 7.0 7.0 7.0 7.0
*1
2.4 -
E1-11 Hz 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
*1
0.0 0.0
E1-12
*2
V 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
*1
0.0 0.0

Table of Contents

Other manuals for YASKAWA CR700