11.8 H: Terminal Functions
690 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
Note:
Refer to H1-xx MFDI Function Selections for the setting values of the MFDI.
You cannot set 20 to 2F [External Fault] to H1-40 to H1-42.
When H1-40 to H1-42 are not used, set H1-40 to H1-42 = F [Not Used].
Multi-function input for digital input option D1-A3 cannot be used simultaneously with function selection for MEMOBUS/Modbus
MFDI 1 to 3.
H1-40: Mbus Reg 15C0h bit0 Input Func
No.
(Hex.)
Name Description
Default
(Range)
H1-40
(0B54)
Mbus Reg 15C0h bit0 Input
Func
Sets MFDI function to set to bit 0 of the MEMOBUS register 15C0(Hex.).
F
(0 - 1FF)
H1-41: Mbus Reg 15C0h bit1 Input Func
No.
(Hex.)
Name Description
Default
(Range)
H1-41
(0B55)
Mbus Reg 15C0h bit1 Input
Func
Sets MFDI function to set to bit 1 of the MEMOBUS register 15C0(Hex.).
F
(0 - 1FF)
H1-42: Mbus Reg 15C0h bit2 Input Func
No.
(Hex.)
Name Description
Default
(Range)
H1-42
(0B56)
Mbus Reg 15C0h bit2 Input
Func
Selects MFDI function assigned to bit 2 of the MEMOBUS register 15C0(Hex.).
F
(0 - 1FF)
MFDI Function Selections
Sets a function set to H1-01 to H1-10.
0: Brake Release Check
Setting Value Function Description
0 Brake Release Check
Set the wiring sequence to turn ON the brake release check when the brake release command turns ON.
2: External Reference 1/2 Selection
Setting Value Function Description
2 External Reference 1/2
Selection
Sets the drive to use Run command source 1/2 or Reference command source 1/2 when in REMOTE Mode.
Note:
When the drive is receiving a Run command, you cannot switch between reference sources.
ON : b1-15 [Frequency Reference Selection 2], b1-16 [Run Command Selection 2]
OFF : b1-01 [Frequency Reference Selection 1], b1-02 [Run Command Selection 1]
3: Multi-Step Speed Reference 1
Setting Value Function Description
3 Multi-Step Speed Reference
1
Uses speed references d1-01 to d1-16 to set a multi-step speed reference.
Note:
Refer to
Setting Procedures for Multi-step Speed Operation on page 622 for more information.
4: Multi-Step Speed Reference 2
Setting Value Function Description
4 Multi-Step Speed Reference
2
Uses speed references d1-01 to d1-16 to set a multi-step speed reference.
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV

Table of Contents