Parameter Details
11
11.6 E: Motor Parameters
YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual 649
E7: Motor 3 Parameters
E7 parameters [Motor 3 Parameters] are used to set induction motor data.
Motor 3 is only available with V/f Control.
E7-04: Motor 3 Maximum Output Frequency
No.
(Hex.)
Name Description
Default
(Range)
E7-04
(1B61)
Motor 3 Maximum Output
Frequency
Set the maximum output frequency for the motor 3.
Determined by E1-03
(40.0 - 590.0 Hz)
E7-05: Motor 3 Maximum Output Voltage
No.
(Hex.)
Name Description
Default
(Range)
E7-05
(1B62)
Motor 3 Maximum Output
Voltage
Sets the maximum output voltage used for motor 3.
Determined by E1-03
(200 V Class: 0.0 - 255.0 V,
400 V Class: 0.0 - 510.0 V)
E7-06: Motor 3 Base Frequency
No.
(Hex.)
Name Description
Default
(Range)
E7-06
(1B63)
Motor 3 Base Frequency
Sets the base frequency used for motor 3.
Determined by E1-03
(0.0 - E7-04)
E7-07: Motor 3 Mid Point A Frequency
No.
(Hex.)
Name Description
Default
(Range)
E7-07
(1B64)
Motor 3 Mid Point A
Frequency
Sets the middle output frequency used for motor 3.
Determined by E1-03
(0.0 - E7-04)
E7-08: Motor 3 Mid Point A Voltage
No.
(Hex.)
Name Description
Default
(Range)
E7-08
(1B65)
Motor 3 Mid Point A
Voltage
Sets the middle output frequency voltage used for motor 3.
Determined by E1-03
(200 V Class: 0.0 - 255.0 V,
400 V Class: 0.0 - 510.0 V)
E7-09: Motor 3 Minimum Output Frequency
No.
(Hex.)
Name Description
Default
(Range)
E7-09
(1B66)
Motor 3 Minimum Output
Frequency
Sets the minimum output frequency for the motor 3.
Determined by E1-03
(0.0 - E7-04)
E7-10: Motor 3 Minimum Output Voltage
No.
(Hex.)
Name Description
Default
(Range)
E7-10
(1B67)
Motor 3 Minimum Output
Voltage
Sets the minimum output voltage for the motor 3.
Determined by E1-03
(200 V Class: 0.0 - 255.0 V,
400 V Class: 0.0 - 510.0 V)
E7-11: Motor 3 Mid Point B Frequency
No.
(Hex.)
Name Description
Default
(Range)
E7-11
(1B68)
Expert
Motor 3 Mid Point B
Frequency
Sets the mid point B frequency used for motor 3.
0.0 Hz
(0.0 - E7-04)
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV

Table of Contents

Other manuals for YASKAWA CR700

Related product manuals