Parameter List
10
10.10 H: Terminal Functions
YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual 499
10.10 H: Terminal Functions
H1: Digital Inputs
No.
(Hex.)
Name Description
Default
(Range)
Ref.
H1-01
(0438)
Terminal S1 Function
Selection
Sets the function for MFDI terminal S1.
40
(0 - 1FF)
687
H1-02
(0439)
Terminal S2 Function
Selection
Sets the function for MFDI terminal S2.
41
(0 - 1FF)
687
H1-03
(0400)
Terminal S3 Function
Selection
Sets the function for MFDI terminal S3.
24
(0 - 1FF)
687
H1-04
(0401)
Terminal S4 Function
Selection
Sets the function for MFDI terminal S4.
14
(0 - 1FF)
687
H1-05
(0402)
Terminal S5 Function
Selection
Sets the function for MFDI terminal S5.
0
(0 - 1FF)
687
H1-06
(0403)
Terminal S6 Function
Selection
Sets the function for MFDI terminal S6.
3
(0 - 1FF)
687
H1-07
(0404)
Terminal S7 Function
Selection
Sets the function for MFDI terminal S7.
4
(0 - 1FF)
687
H1-08
(0405)
Terminal S8 Function
Selection
Sets the function for MFDI terminal S8.
9
(0 - 1FF)
687
H1-09
(0406)
Terminal S9 Function
Selection
Sets the function for MFDI terminal S9.
F
(0 - 1FF)
688
H1-10
(0407)
Terminal S10 Function
Selection
Sets the function for MFDI terminal S10.
F
(0 - 1FF)
688
H1-21
(0B70)
Terminal S1 Function
Select 2
Sets the second function for MFDI terminal S1.
F
(0 - 1FF)
688
H1-22
(0B71)
Terminal S2 Function
Select 2
Sets the second function for MFDI terminal S2.
F
(0 - 1FF)
688
H1-23
(0B72)
Terminal S3 Function
Select 2
Sets the second function for MFDI terminal S3.
F
(0 - 1FF)
688
H1-24
(0B73)
Terminal S4 Function
Select 2
Sets the second function for MFDI terminal S4.
F
(0 - 1FF)
688
H1-25
(0B74)
Terminal S5 Function
Select 2
Sets the second function for MFDI terminal S5.
F
(0 - 1FF)
688
H1-26
(0B75)
Terminal S6 Function
Select 2
Sets the second function for MFDI terminal S6.
F
(0 - 1FF)
689
H1-27
(0B76)
Terminal S7 Function
Select 2
Sets the second function for MFDI terminal S7.
F
(0 - 1FF)
689
H1-28
(0B77)
Terminal S8 Function
Select 2
Sets the second function for MFDI terminal S8.
F
(0 - 1FF)
689
H1-29
(0B78)
Terminal S9 Function
Select 2
Sets the second function for MFDI terminal S9.
F
(0 - 1FF)
689
H1-30
(0B79)
Terminal S10 Function
Select 2
Sets the second function for MFDI terminal S10.
F
(0 - 1FF)
689
H1-40
(0B54)
Mbus Reg 15C0h bit0
Input Func
Sets MFDI function to set to bit 0 of the MEMOBUS register 15C0(Hex.).
F
(0 - 1FF)
690
H1-41
(0B55)
Mbus Reg 15C0h bit1
Input Func
Sets MFDI function to set to bit 1 of the MEMOBUS register 15C0(Hex.).
F
(0 - 1FF)
690
H1-42
(0B56)
Mbus Reg 15C0h bit2
Input Func
Selects MFDI function assigned to bit 2 of the MEMOBUS register 15C0(Hex.).
F
(0 - 1FF)
690
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV

Table of Contents