10.20 Parameters Changed by o2-04 [Drive Model (KVA) Selection]
562 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
No. Name Unit Default
- Drive Model - 4002 4003 4005 4006
o2-04
Drive Model (KVA)
Selection
Hex. 92 93 94 95
Motor 1: E2-11
Motor 2: E4-11
Motor 3: E7-31
Motor Rated Power kW 0.4 1.1 1.5 2.2
Motor 1: E2-10
Motor 2: E4-10
Motor Iron Loss W 14 26 53 77
L2-03
Minimum Baseblock
Time
s 0.2 0.3 0.4 0.5
L2-05
Undervoltage Detection
Lvl (Uv1)
- 380 380 380 380
L3-24
Motor Accel Time @
Rated Torque
s 0.178 0.142 0.166 0.145
L8-02 Overheat Alarm Level °C 100 105 112 110
L8-09
Output Ground Fault
Detection
- 1 1 1 1
L8-38
Carrier Frequency
Reduction
- 2 2 2 2
L8-39
Carrier Freq Reduction
during oL
- 2 2 2 2
n1-01
Hunting Prevention
Selection
- 1 1 1 1
n1-03
Hunting Prevention
Time Constant
ms 10 10 10 10
n1-16
Hunting Prevention
High Fc Gain
- 0.50 0.50 0.50 0.50
n2-01
Automatic Freq
Regulator Gain(F)
- 1.00 1.00 1.00 1.00
n5-02
Motor Inertia
Acceleration Time
s 0.178 0.142 0.166 0.145
No. Name Unit Default
- Drive Model - 4007 4009 4015 4018
o2-04
Drive Model (KVA)
Selection
Hex. 96 97 99 9A
Motor 1: E2-11
Motor 2: E4-11
Motor 3: E7-31
Motor Rated Power kW 3.0 4.0 5.5 7.5
Motor 1: C5-17
Motor 2: C5-37
Motor Inertia kgm
2
0.0158 0.0158 0.026 0.037
C6-02
Carrier Frequency
Selection
- 1 1 1 1
E1-01
Input AC Supply
Voltage
V 400 400 400 400
Motor 1: E2-01
Motor 2: E4-01
Motor 3: E7-21
Motor Rated Current
(FLA)
A 5.7 7 9.8 13.3
Motor 1: E2-02
Motor 2: E4-02
Motor Rated Slip Hz 2.7 2.7 1.5 1.3
Motor 1: E2-03
Motor 2: E4-03
Motor No-Load Current A 1.9 2.3 2.6 4
Motor 1: E2-05
Motor 2: E4-05
Motor 3: E7-25
Motor Line-to-Line
Resistance
Ω 4.360 3.333 1.595 1.152
Motor 1: E2-06
Motor 2: E4-06
Motor Leakage
Inductance
% 19 19.3 18.2 15.5
Motor 1: E2-10
Motor 2: E4-10
Motor Iron Loss W 105 130 193 263
L2-03
Minimum Baseblock
Time
s 0.5 0.6 0.7 0.8
L2-05
Undervoltage Detection
Lvl (Uv1)
- 380 380 380 380