2.9 Change the Drive Enclosure Type
52 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
A - Back hooks
B - Front hooks
C - Back side of top protective cover
D - Drive front side
E - Mark
F - Temporary placement holes
Figure 2.33 Install the Top Protective Cover
Install the Conduit Bracket
Remove the keypad, connector, and front cover before you do these steps.
1. Remove the screws that install the protective covers to the drive.
A - Screws
Figure 2.34 Remove the Screws that Install the Protective Cover
2. Remove the knock-out holes on the UL Type 1 base before you install the kit.
Refer to
Remove the Knock-Out Holes on page 51 for more information.
3. Align the screw holes of the UL Type 1 base with the screw holes on the drive and safety the UL Type 1
base to the drive with the screws.
Tighten the screws to a correct tightening torque:
0.98 Nm to 1.33 Nm (8.67 lbfin to 11.77 lbfin)
A - UL Type 1 base
B - Knock-out holes
C - Screw holes
Figure 2.35 Install the UL Type 1 Base