11.3 b: Application
596 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
b4-03: Terminal M1-M2 ON-Delay Time
No.
(Hex.)
Name Description
Default
(Range)
b4-03
(0B30)
Expert
Terminal M1-M2 ON-
Delay Time
Sets the delay time to activate the contact after the function set in H2-01 activates.
0 ms
(0 - 65000 ms)
b4-04: Terminal M1-M2 OFF-Delay Time
No.
(Hex.)
Name Description
Default
(Range)
b4-04
(0B31)
Expert
Terminal M1-M2 OFF-
Delay Time
Sets the delay time to deactivate the contact after the function set in H2-01 deactivates.
0 ms
(0 - 65000 ms)
b4-05: Terminal M3-M4 ON-Delay Time
No.
(Hex.)
Name Description
Default
(Range)
b4-05
(0B32)
Expert
Terminal M3-M4 ON-
Delay Time
Sets the delay time to activate the contact after the function set in H2-02 activates.
0 ms
(0 - 65000 ms)
b4-06: Terminal M3-M4 OFF-Delay Time
No.
(Hex.)
Name Description
Default
(Range)
b4-06
(0B33)
Expert
Terminal M3-M4 OFF-
Delay Time
Sets the delay time to deactivate the contact after the function set in H2-02 deactivates.
0 ms
(0 - 65000 ms)
b4-07: Terminal M5-M6 ON-Delay Time
No.
(Hex.)
Name Description
Default
(Range)
b4-07
(0B34)
Expert
Terminal P2 ON-Delay
Time
Sets the delay time to activate the contact after the function set in H2-03 activates.
0 ms
(0 - 65000 ms)
b4-08: Terminal M5-M6 OFF-Delay Time
No.
(Hex.)
Name Description
Default
(Range)
b4-08
(0B35)
Expert
Terminal P2 OFF-Delay
Time
Sets the delay time to deactivate the contact after the function set in H2-03 deactivates.
0 ms
(0 - 65000 ms)
b4-09: Terminal P1-C1 ON-Delay Time
No.
(Hex.)
Name Description
Default
(Range)
b4-09
(0B36)
Expert
Terminal P2-C2 ON-Delay
Time
Sets the delay time to activate the contact after the function set in H2-04 activates.
0 ms
(0 - 65000 ms)
b4-10: Terminal P1-C1 OFF-Delay Time
No.
(Hex.)
Name Description
Default
(Range)
b4-10
(0B37)
Expert
Terminal P2-C2 OFF-Delay
Time
Sets the delay time to deactivate the contact after the function set in H2-04 deactivates.
0 ms
(0 - 65000 ms)
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV

Table of Contents