Mechanical & Electrical Installation
2
2.9 Change the Drive Enclosure Type
YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual 63
A - M5 × 12 pan head screws B - Base
Figure 2.60 Install the Base on the Stay Brackets
3. Use the included screws to install the UL Type 1 base to the drive.
Tighten the screws to a correct tightening torque:
• 1.96 N∙m to 2.53 N∙m (17.35 lbf∙in to 22.39 lbf∙in)
A - M5 × 12 pan head screws
Figure 2.61 Safety the Base
4. Use the included screws to install the UL Type 1 conduit bracket to the base.
Tighten the screws to a correct tightening torque:
• 0.98 N∙m to 1.33 N∙m (8.67 lbf∙in to 11.77 lbf∙in)
A - Conduit bracket B - M4 × 10 pan head screws
Figure 2.62 Install the Conduit Bracket
5. Use the included screws to install the front cover to the base.
While slightly lifting the front cover, tighten the screws to a correct tightening torque:
• 0.98 N∙m to 1.33 N∙m (8.67 lbf∙in to 11.77 lbf∙in)