Parameter Details
11
11.8 H: Terminal Functions
YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual 731
Note:
The gain for each terminal A1, A2, and A3 is configured independently with H3-03 [Terminal A1 Gain Setting], H3-11 [Terminal A2
Gain Setting], and H3-07 [Terminal A3 Gain Setting]. The bias for each terminal A1, A2, and A3 is configured independently with H3-
04 [Terminal A1 Bias Setting], H3-12 [Terminal A2 Bias Setting], and H3-08 [Terminal A3 Bias Setting].
Figure 11.74 Output Voltage Bias through Analog Input
5: Accel/Decel Time Gain
Setting Value Function Description
5 Accel/Decel Time Gain
Enters a signal to adjust the gain used for C1-01 to C1-08 [Acceleration/Deceleration Times 1 to 4] and C1-09 [Fast Stop Time]
when the full scale analog signal (10 V or 20 mA) is 100%.
When you enable C1-01 [Acceleration Time 1], the acceleration time is:
Acceleration Time 1 = Setting value of C1-01 × acceleration and deceleration time gain / 100
Figure 11.75 Acceleration/Deceleration Time Gain through Analog Input
6: DC Injection Braking Current
Setting Value Function Description
6 DC Injection Braking
Current
Enters a signal to adjust the current level used for DC Injection Braking when the drive rated output current is 100%.
Note:
When you set this function, it will disable the setting value of b2-02 [DC Injection Braking Current].
Figure 11.76 DC Injection Braking Current through Analog Input
7: Torque Detection Level
Setting Value Function Description
7 Torque Detection Level
Enters a signal to adjust the overtorque detection level.
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV