EasyManuals Logo

YASKAWA CR700 Technical Manual

YASKAWA CR700
886 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #770 background imageLoading...
Page #770 background image
11.10 n: Special Adjustment
770 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
Adjust this parameter in these conditions:
When n1-01 = 1, 2 [Hunting Prevention Selection = Enabled (Normal), Enabled (High Carrier Frequency)]: If
oscillation occurs when you operate a motor with a light load, increase the setting value in 0.1-unit increments.
When n1-01 = 1, 2, if the motor stalls: Decrease the setting value in 0.1-unit increments.
n1-08: Current Detection Method
No.
(Hex.)
Name Description
Default
(Range)
n1-08
(1105)
Expert
Current Detection Method
Sets how the drive decreases the motor vibration that is caused by leakage current. Usually it is
not necessary to change this parameter.
0
(0, 1)
0 : 2-Phases
1 : 3-Phases
Note:
The n1-08 = 1 setting is effective in suppressing motor vibrations due to leakage current when the wiring distance is long.
n1-13: DC Bus Stabilization Control
No.
(Hex.)
Name Description
Default
(Range)
n1-13
(1B59)
Expert
DC Bus Stabilization
Control
Sets the oscillation suppression function for the DC bus voltage.
0
(0, 1)
0 : Disabled
1 : Enabled
Note:
If the DC bus voltage does not become stable with light loads and the drive detects ov [Overvoltage], set this parameter to 1.
n1-14: DC Bus Stabilization Time
No.
(Hex.)
Name Description
Default
(Range)
n1-14
(1B5A)
Expert
DC Bus Stabilization Time
Adjusts the responsiveness of the oscillation suppression function for the DC bus voltage. Set n1-
13 = 1 [DC Bus Stabilization Control = Enabled] to enable this parameter.
100.0 ms
(50.0 - 500.0 ms)
Note:
Adjust this parameter in 100 ms increments.
n1-15: PWM Voltage Offset Calibration
No.
(Hex.)
Name Description
Default
(Range)
n1-15
(0BF8)
Expert
PWM Voltage Offset
Calibration
Sets the calibration method that the drive uses to decrease torque/current ripple.
Determined by A1-02
(0 - 2)
This calibration function lets the drive suppress the torque ripple of a motor. Usually it is not necessary to change
this setting.
0 : No Calibration
1 : One Time Calibrate at Next Start
2 : Calibrate Every Time at Start
n1-16: Hunting Prevention High Fc Gain
No.
(Hex.)
Name Description
Default
(Range)
n1-16
(0BFB)
Hunting Prevention High Fc
Gain
Sets the gain for the hunting prevention function. This parameter functions best with a high carrier
frequency. Usually it is not necessary to change this parameter.
Determined by o2-04
(0.00 - 2.50)
Set n1-01 = 2 [Hunting Prevention Selection = Enabled (High Carrier Frequency)] to enable this function.
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV

Table of Contents

Other manuals for YASKAWA CR700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA CR700 and is the answer not in the manual?

YASKAWA CR700 Specifications

General IconGeneral
BrandYASKAWA
ModelCR700
CategoryDC Drives
LanguageEnglish

Related product manuals