Parameter Details
11
11.11 o: Keypad-Related Settings
YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual 787
■ o1-44: 2nd Monitor Area Setting
No.
(Hex.)
Name Description
Default
(Range)
o1-44
(11C4)
RUN
2nd Monitor Area Setting
Sets the horizontal axis value used to display the monitor set in o1-25 [Custom Monitor 2] as a
bar graph. This parameter is only available with an LCD keypad.
100.0%
(0.0 - 100.0%)
■ o1-45: 3rd Monitor Area Selection
No.
(Hex.)
Name Description
Default
(Range)
o1-45
(11C5)
RUN
3rd Monitor Area Selection
Sets the horizontal axis value used to display the monitor set in o1-26 [Custom Monitor 3] as a
bar graph. This parameter is only available with an LCD keypad.
0
(0 - 1)
0 : +/- Area ( - o1-46 ~ o1-46 )
1 : + Area ( 0 ~ o1-46 )
■ o1-46: 3rd Monitor Area Setting
No.
(Hex.)
Name Description
Default
(Range)
o1-46
(11C6)
RUN
3rd Monitor Area Setting
Sets the horizontal axis value used to display the monitor set in o1-26 [Custom Monitor 3] as a
bar graph. This parameter is only available with an LCD keypad.
100.0%
(0.0 - 100.0%)
■ o1-47: Trend Plot 1 Scale Minimum Value
No.
(Hex.)
Name Description
Default
(Range)
o1-47
(11C7)
RUN
Trend Plot 1 Scale
Minimum Value
Sets the minimum value for the vertical axis used to display a trend plot from the monitor selected
with o1-24. This parameter is only available with an LCD keypad.
-100.0%
(-300.0 - +99.9%)
■ o1-48: Trend Plot 1 Scale Maximum Value
No.
(Hex.)
Name Description
Default
(Range)
o1-48
(11C8)
RUN
Trend Plot 1 Scale
Maximum Value
Sets the maximum value for the vertical axis used to display the monitor that was set in o1-24
[Custom Monitor 1] as a trend plot. This parameter is only available with an LCD keypad.
100.0%
(-299.9 - +300.0%)
Note:
Parameter o1-47 [Trend Plot 1 Scale Minimum Value] sets the lower limit. The lower limit is (o1-47 + 0.1)%.
■ o1-49: Trend Plot 2 Scale Minimum Value
No.
(Hex.)
Name Description
Default
(Range)
o1-49
(11C9)
RUN
Trend Plot 2 Scale
Minimum Value
Sets the minimum value for the vertical axis used to display a trend plot from the monitor selected
with o1-25. This parameter is only available with an LCD keypad.
-100.0%
(-300.0 - +99.9%)
■ o1-50: Trend Plot 2 Scale Maximum Value
No.
(Hex.)
Name Description
Default
(Range)
o1-50
(11CA)
RUN
Trend Plot 2 Scale
Maximum Value
Sets the maximum value for the vertical axis used to display the monitor that was set in o1-25
[Custom Monitor 2] as a trend plot. This parameter is only available with an LCD keypad.
100.0%
(-299.9 - +300.0%)
Note:
Parameter o1-49 [Trend Plot 2 Scale Minimum Value] sets the lower limit. The lower limit is (o1-49 + 0.1)%.