11.12 T: Auto-Tuning
804 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
T3-04: System Response Frequency
No.
(Hex.)
Name Description
Default
(Range)
T3-04
(0763)
System Response
Frequency
This parameter uses the load inertia value from the Inertia Tuning process to automatically
calculate and set C5-01 [ASR Proportional Gain 1].
10.0 Hz
(0.1 - 50.0 Hz)
Oscillation may result if the value input here is too high.