EasyManuals Logo

YASKAWA NX100 Instructions

YASKAWA NX100
308 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #162 background imageLoading...
Page #162 background image
8.15 Numeric Key Customize Function
8-96
Group (4-bit/8-bit) Output Allocation
Set this function in the KEY ALLOCATION (SIM) window.
Analog Output Allocation
Set this function in the KEY ALLOCATION (SIM) window.
Operation Explanation
1 Move the cursor to the “FUNC-
TION” of the key to be allo-
cated and press [SELECT].
A selection list appears.
2 Select “4 BIT OUTPUT” or “8
BIT OUTPUT”.
The output No. and output value are displayed in the “ALLOCA-
TION CONTENT”.
To change the output No. or output value, move the cursor to the
No. or value and press [SELECT]. Numeric values can now be
entered. Input the number or value to be changed, and press
[ENTER].
Operation Explanation
1 Move the cursor to the “FUNC-
TION” of the key to be allo-
cated and press [SELECT].
A selection list appears.
2 Select “ANALOG OUTPUT”. The output port number and the output voltage value are dis-
played in the “ALLOCATION CONTENT”.
To change the output port No. or output voltage value, move the
cursor to the No. or voltage value and press [SELECT]. Numeric
values can now be entered. Input the number or voltage value to
be changed, and press [ENTER].
Short CutMain Menu
KEY ALLOCATION(SIM)
DATA EDIT DISPLAY UTILITY
APPLI. NO. : 2
0
1
2
3
4
5
6
7
8
9
.
KEY FUNCTION ALLOCATION CONTENT
PAGE
TIME 0.01 sec
OUT
NO. 1
NO. 1
NO. 1
NO. 1
0
ALTERNATE
MOMENTARY
PULSE
4BIT OUTPUT
MAKER
MAKER
MAKER
MAKER
MAKER
MAKER
MAKER
MAKER
Short CutMain Menu
KEY ALLOCATION(SIM)
DATA EDIT DISPLAY UTILITY
APPLI. NO. : 2
0
1
2
3
4
5
6
7
8
9
.
KEY FUNCTION ALLOCATION CONTENT
PAGE
0
ALTERNATE
MOMENTARY
PULSE
4BIT OUTPUT
ANALOG OUT
MAKER
MAKER
MAKER
MAKER
MAKER
MAKER
MAKER
TIME 0.01 sec
OUT
OUT
NO. 1
NO. 1
NO. 1
NO. 1
NO. 1
0.00

Table of Contents

Other manuals for YASKAWA NX100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA NX100 and is the answer not in the manual?

YASKAWA NX100 Specifications

General IconGeneral
ManufacturerYASKAWA
ModelNX100
Operating Temperature0 to 45°C
Humidity20 to 80% RH (non-condensing)
Communication InterfacesEthernet
Safety StandardsISO 10218-1
Power Supply200-230V AC, 50/60Hz
Storage Temperature60°C

Related product manuals