13.3 CPU Unit
13-24
Full-speed Test
This signal is used to reset the slow speed limit for the test run in the teach mode.
If this signal input circuit is short-circuited, the speed of the test run becomes 100% in the
teach mode.
If this signal’s circuit is open, the status SSP input signal determines the slow speed: The first
slow speed (16%) or second slow speed (2%).
Connection for Full-speed Test
Slow Speed Mode Selection
This signal is used to determine the speed of the test run when the FST (full-speed test) signal
input circuit is open.
Open: Second slow speed (2%)
Short-circuit: First slow speed (16%)
Connection for Slow Speed Mode Selection
Turned ON/OFF
at the same time
Full-speed test
-23
-24
-25
-26
+24V2
FST1
FST2
024V
NX100
Robot system input
terminal block
MXT
JANCD-
NBB01
JANCD-
NIF01-
-27
-28
+24V2
SSP
Slow speed mode selection
Remove the jumper cable
Robot system input
terminal block
MXT
NX100
JANCD-
NBB01
JANCD-
NIF01-

Table of Contents

Other manuals for YASKAWA NX100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA NX100 and is the answer not in the manual?

YASKAWA NX100 Specifications

General IconGeneral
ManufacturerYASKAWA
ModelNX100
Operating Temperature0 to 45°C
Humidity20 to 80% RH (non-condensing)
Communication InterfacesEthernet
Safety StandardsISO 10218-1
Power Supply200-230V AC, 50/60Hz
Storage Temperature60°C

Related product manuals