9.3 Automatic Backup Function
9-17
9.3.3 Loading the Backup Data from the CompactFlash
Loading Procedure
Restore the backup data saved in the CompactFlash to the NX100 in maintenance mode.
Note that executing "SYSTEM RESTORE" replaces the current CMOS data with the data
of the file "CMOSBK.BIN"
or "CMOSBK??.BIN" (?? denotes figures) in the CompactFlash.
After "CMOSBK.BIN" has been loaded, check if the new data is the same as the previ-
ously saved data in the CMOS, and call the master job to confirm that the current manipu-
lator position is correct and safe. Then, start moving the manipulator.
Operation Explanation
1 Insert the CompactFlash with
the backup data in the Com-
pactFlash slot on the program-
ming pendant.
The backup data is stored under the file name "CMOSBK.BIN" or
"CMOSBK??.BIN" (?? denotes figures.)
2 Turn ON the NX100 power
supply while pressing [MAIN
MENU].
3 Change the security mode to
the management mode.
4 Select {TOOL} under the main
menu.
The sub menu appears.
CAUTION