8.15 Numeric Key Customize Function
8-97
Analog Incremental Output Allocation
Set this function in the KEY ALLOCATION (SIM) window.
Operation Explanation
1 Move the cursor to the “FUNC-
TION” of the key to be allo-
cated and press [SELECT].
A selection list appears.
2 Select “ANALOG INC OUT-
PUT.”
The output port No. and incremental value are displayed in the
“ALLOCATION CONTENT”.
To change the output port No. or incremental value, move the cur-
sor to the No. or incremental value and press [SELECT].
Numeric values can now be entered. Input the number or incre-
mental value to be changed, and press [ENTER].
Short CutMain Menu
KEY ALLOCATION(SIM)
DATA EDIT DISPLAY UTILITY
APPLI. NO. : 2
0
1
2
3
4
5
6
7
8
9
.
KEY FUNCTION ALLOCATION CONTENT
PAGE
ALTERNATE
MOMENTARY
PULSE
4BIT OUTPUT
ANALOG OUT
ANALOG INC
MAKER
MAKER
MAKER
MAKER
MAKER
MAKER
TIME 0.01 sec
OUT
OUT
NO. 1
NO. 1
NO. 1
NO. 1
NO. 1
0.00
1.00
NO. 1
INC
0

Table of Contents

Other manuals for YASKAWA NX100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA NX100 and is the answer not in the manual?

YASKAWA NX100 Specifications

General IconGeneral
ManufacturerYASKAWA
ModelNX100
Operating Temperature0 to 45°C
Humidity20 to 80% RH (non-condensing)
Communication InterfacesEthernet
Safety StandardsISO 10218-1
Power Supply200-230V AC, 50/60Hz
Storage Temperature60°C

Related product manuals