n DB
A data block (axis DB) for configuration and status data must be created for each axis
of a drive. The data block consists of the following data structures:
UDT 872 - VMC_ConfigSigma7EC_REF
The data structure describes the structure of the configuration of the drive.
Specific data structure for Sigma-7 EtherCAT.
UDT 860 - MC_AXIS_REF
The data structure describes the structure of the parameters and status informa-
tion of drives.
General data structure for all drives and bus systems.
n FB 873 - VMC_InitSigma7S_EC
The Initt block is used to configure an axis.
Specific block for Sigma-7S EtherCAT.
The configuration data for the initialization must be stored in the axis DB.
n FB 872 - VMC_KernelSigma7_EC
The Kernel block communicates with the drive via the appropriate bus system,
processes the user requests and returns status messages.
Specific block for Sigma-7 EtherCAT.
The exchange of the data takes place by means of the axis DB.
n FB 860 - VMC_AxisControl
General block for all drives and bus systems.
Supports simple motion commands and returns all relevant status messages.
The exchange of the data takes place by means of the axis DB.
For motion control and status query, via the instance data of the block you can
link a visualization.
In addition to the FB 860 - VMC_AxisControl, PLCopen blocks can be used.
n FB 800 ... FB 838 - PLCopen
The PLCopen blocks are used to program motion sequences and status queries.
General blocks for all drives and bus systems.
Programming
1. Go to the service area of www.vipa.com.
2. Download the Simple Motion Control library from the download area at ‘VIPA Lib’ .
3.
Open the dialog window for ZIP file selection via ‘File è Retrieve’.
4. Select the according ZIP file and click at [Open].
5. Specify a target directory in which the blocks are to be stored and start the unzip
process with [OK].
Open the library after unzipping and drag and drop the following blocks into
‘Blocks’ of your project:
n Sigma-7S EtherCAT:
UDT 872 - VMC_ConfigSigma7EC_REF
FB 872 - VMC_KernelSigma7_EC
FB 873 - VMC_InitSigma7S_EC
n Axis Control
UDT 860 - MC_AXIS_REF
Blocks for your movement sequences
Include library
Copy blocks into project
VIPA SPEED7
Motion control - Simple Motion Control Library
Usage Sigma-5/7 EtherCAT > Usage Sigma-7S EtherCAT