With the exception of blocks DB 99 and FB 877, you must create the blocks listed below
for each connected inverter drive:
n FB 881 - VMC_InitV1000_RTU
Ä
507
The FB 881 - VMC_InitV1000_RTU initializes the corresponding inverter drive
with the user data.
Before an inverter drive can be controlled, it must be initialized.
UDT 881 - VMC_ConfigV1000RTU_REF
Ä
504
UDT 879 - VMC_AxisRTU_REF
Ä
504
n FB 879 - VMC_ReadParameter_RTU
Ä
506
With this FB you have read access to the parameters of an inverter drive, which is
connected serially via Modbus RTU.
The read data are recorded in a data block.
UDT 879 - VMC_AxisRTU_REF
Ä
504
n FB 880 - VMC_WriteParameter_RTU
Ä
507
With this FB you have read access to the parameters of an inverter drive, which is
connected serially via Modbus RTU.
The data to be written must be stored in a data block.
UDT 879 - VMC_AxisRTU_REF
Ä
504
n DB 100 - A1_V1000
For each inverter drive, which is serially connected via Modbus RTU, a data block
must be created.
UDT 879 - VMC_AxisRTU_REF
Ä
504
UDT 881 - VMC_ConfigV1000RTU_REF
Ä
504
n FB 882 - VMC_AxisControlV1000_RTU
Ä
509
With this block, you can control an inverter drive, which is serially connected via
Modbus RTU and check its status.
UDT 881 - VMC_ConfigV1000RTU_REF
Ä
504
UDT 879 - VMC_AxisRTU_REF
Ä
504
UDT 878 - VMC_ComObjectRTU_REF
Ä
504
n DB 99 - ComDataSlaves
For the communication data of all the inverter drives (max. 8), which are serially
connected via Modbus RTU, a common data block is to be created.
UDT 877 - VMC_ComSlavesRTU_REF
Ä
504
UDT 878 - VMC_ComObjectRTU_REF
Ä
504
n FB 877 - VMC_ComManager_RTU
Ä
505
The device ensures that only 1 inverter drive (Modbus slave) can use the serial
interface. If several inverter drives are used, this block, as communication man-
ager, sends the jobs to the respective Modbus slaves and evaluates their
responses.
UDT 877 - VMC_ComSlavesRTU_REF
Ä
504
OB 1
VIPA SPEED7
Motion control - Simple Motion Control Library
Usage inverter drive via Modbus RTU > Usage in Siemens SIMATIC Manager
HB00 | OPL_SP7 | Operation list | en | 18-30 478