xx1000000929
Remove the attachment screws securing
motor axis 6 and remove the motor.
Note
Do not remove the attachment screws se-
curing the motor bracket.
16
A: Attachment screws, bracket
B: Flexible coupling
C: Attachment screws, motor (3
pcs)
D: Cylindrical pins (2 pcs)
E: Motor axis 6
Refitting axis-6 motor and wrist unit
Use this procedure to refit the axis-6 motor and the wrist unit.
InformationAction
xx1000000929
Place the motor axis 6 into the flexible
coupling axis 6.
1
A: Attachment screws, bracket
B: Flexible coupling
C: Attachment screws, motor (3
pcs)
D: Cylindrical pins (2 pcs)
E: Motor axis 6
Tightening torque: 6 NmSecure the motor with its attachment