Standing Conditions
T-CV-L-HT__15MIN (Line/MS-CV
15M)
The corresponding SNMP name for this condition is “thres15MinExceededSonetLineCV”.
AIDTYPE Default
Severity
Probable Cause Suggested Corrective Action
CH MN The number of
line/multiplex
section layer
coding violations
detected by the
receiver exceeds
the provisioned
15-minute
threshold value.
This condition is informative and no
immediate corrective action is required.
If the condition persists across multiple
intervals, it may indicate an imminent
failure of a more serious nature, including
failure of either the source or receiving
plug or module or a failure in one of the
cables along the path between the
source and the receiver.
To ensure that the condition is being
reported only under the correct
circumstances, verify that the 15-minute
threshold level is provisioned correctly.
Table 437: T-CV-L-HT__15MIN (Standing Condition)
T-CV-PCS-HT__15MIN (PCS-CV 15M)
The corresponding SNMP name for this condition is
thres15MinExceededPhysConvCV”.
AIDTYPE Default
Severity
Probable Cause Suggested Corrective Action
CH MN The number of
Physical Coding
Sub-layer coding
violations
detected by the
receiver exceeds
the provisioned
15-minute
threshold value.
This condition is informative and no
immediate corrective action is required.
If the condition persists across multiple
intervals, it may indicate an imminent
failure of a more serious nature, including
failure of either the source or receiving
plug or module or a failure in one of the
cables along the path between the
source and the receiver.
To ensure that the condition is being
reported only under the correct
circumstances, verify that the 15-minute
threshold level is provisioned correctly.
Table 438: T-CV-PCS-HT__15MIN (Standing Condition)