EasyManua.ls Logo

Adva FSP 3000R7 - SQM-LP (Path LO-Loss of Sequence); SQM-LP Details and Probable Causes

Adva FSP 3000R7
1134 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Standing Conditions
SQM-LP (Path LO-Loss of Sequence)
The corresponding SNMP name for this condition is “lossofSequenceLowerOrderPath.
AIDTYPE Default
Severity
Probable Cause
VC3 CR The path is configured as a member of a virtual concatenation
bundle and the sequence indicator values have been found to
be in error. The most probable causes of this are:
A difference in the provisioned bundle size, member
paths, or order of member paths between the near and far-
end,
A difference in the provisioned properties of the GFP
mapping facilities between the near and far-end,
Impairment of the received signal affecting one or more of
the paths,
Mis-connection of cross-connected paths used to form the
virtual concatenation bundle at an intermediate cross-
connection point between the near and far-end,
Equipment failure at the near or far-end.
Table 402: SQM-LP Details and Probable Causes
982 FSP 3000R7 Maintenance and Troubleshooting Manual - Product Release 16.2 - Document Issue A