Standing Conditions
SPEQ-PPC-OOR (Span-Adopt Exceeds
PPC)
The corresponding SNMP name for this condition is “ppcOutOfRangeSpeq”.
AIDTYPE Default
Severity
Probable Cause Suggested Corrective Action
SPEQ MJ The power-per-
channel value
which was adopted
during configuration
of the span
equalization entity
is outside of the
allowed value
range.
1 Review the span equalization
provisioning values for the power
per channel, set point and gain
calibration settings and correct any
erroneous values.
2 Verify that any dispersion
compensating elements or optical
pads along the incoming signal path
are of the correct type and value
and replace any which do not
conform to the engineered values.
3 Progressing upstream towards the
optical source, verify the optical
power levels of the signals supplied
as input to the amplifier supporting
the entity reporting this condition.
Verify that all optical fiber cables
are correctly attached, that they are
undamaged, are not bent, and that
the fiber connectors themselves are
clean and undamaged. At each
equipment module, verify that the
optical transmit power of the signal
sent towards the entity reporting the
condition is within specifications
and adjust provisioning values
found in error as necessary, or
replace any modules which fail to
meet their required optical
performance.
4 At the optical source(s), verify that
the correct optical source is in use
and that it is operating within
specifications. Replace any optical
source (module or pluggable) found
to be failed or outside its operating
specifications.
Table 396: SPEQ-PPC-OOR (Standing Condition)
976 FSP 3000R7 Maintenance and Troubleshooting Manual - Product Release 16.2 - Document Issue A