Transient Conditions
T-UAS-TCMA-HT__1DAY (TCM_A-UAS
Day)
AIDTYPE Probable Cause Suggested Corrective Action
CH The number of
unavailable seconds
measured in the
Tandem Connection
Monitoring instance
A (TCMA) layer
exceeds the
provisioned 1-Day
threshold value.
This condition is informative and requires no
immediate corrective action. If the condition
persists across multiple intervals, it may indicate
a failure at the source or receiving plug or module,
or a failure in one of the cables along the path
between the source and the receiver.
To ensure that the condition is reported only under
the correct circumstances, verify that the 1-Day
threshold level is provisioned correctly.
Table 670: T-UAS-TCMA-HT__1DAY (Transient Condition)
T-UAS-TCMB-HT__1DAY (TCM_B-UAS
Day)
AIDTYPE Probable Cause Suggested Corrective Action
CH The number of
unavailable seconds
measured in the
Tandem Connection
Monitoring instance B
(TCMB) layer exceeds
the provisioned 1-Day
threshold value.
This condition is informative and requires no
immediate corrective action. If the condition
persists across multiple intervals, it may
indicate a failure at the source or receiving
plug or module, or a failure in one of the cables
along the path between the source and the
receiver.
To ensure that the condition is reported only
under the correct circumstances, verify that
the 1-Day threshold level is provisioned
correctly.
Table 671: T-UAS-TCMB-HT__1DAY (Transient Condition)
FSP 3000R7 Maintenance and Troubleshooting Manual - Product Release 16.2 - Document Issue A 1127