Standing Conditions
T-LSRTEMP2-FHT (Laser2-
Temperature High)
The corresponding SNMP name for this condition is “pumpLaser2TempTooHigh”.
AIDTYPE Default
Severity
Probable Cause Suggested Corrective Action
OM MN The temperature
of the second-
stage lasers
providing optical
pump power for
the optical
amplifier
supporting the
facility is above
the specified
operating range.
1 Verify that the equipment operating
environment for the shelf containing
the module meets specifications,
and that the air filter is clean and
unobstructed.
2 Verify that there are no abnormal
conditions or failures of the fan units
within the shelf containing the
module.
3 Verify that the module placement
and that the surrounding equipment
contained within the same shelf
conform to the product’s engineering
guidelines.
4 Replace the module supporting the
facility.
Table 462: T-LSRTEMP2-FHT (Standing Condition)
T-LSRTEMP2-FLT (Laser2-
Temperature Low)
The corresponding SNMP name for this condition is “pumpLaser2TempTooLow”.
AIDTYPE Default
Severity
Probable
Cause
Suggested Corrective Action
OM MN The
temperature of
the second-
stage lasers
providing
optical pump
power for the
optical amplifier
supporting the
facility is below
the specified
operating range.
1 Verify that the equipment operating
environment for the shelf containing the
module meets specifications, and that
the air filter is clean and unobstructed.
2 Verify that there are no abnormal
conditions or failures of the fan units
within the shelf containing the module.
3 Verify that the module placement and
that the surrounding equipment
contained within the same shelf
conform to the product’s engineering
guidelines.
4 Replace the module supporting the
facility.
Table 463: T-LSRTEMP2-FLT (Standing Condition)
1024 FSP 3000R7 Maintenance and Troubleshooting Manual - Product Release 16.2 - Document Issue A