Standing Conditions
FC-LOS (Fiber-Loss of Signal)
The corresponding SNMP name for this condition is “fiberConnLos.
AIDTYPE Default
Severity
Probable Cause Suggested Corrective Action
PTP MN The far-end fiber detect
termination point entity
has been provisioned to
disable the fiber detect
feature, has been
placed into a manually
out-of-service disabled
state, or has
experienced an
equipment failure
affecting the fiber
detection signal optical
source.
1 Verify that the fiber detection
termination point entity at the
far-end of the fiber is properly
provisioned, is in-service, and
has the fiber detect feature
enabled. Correct any
provisioning errors.
2 If the condition still fails to
clear, replace the far-end
module.
Table 184: FC-LOS (Standing Condition)
FC-OPT-SF (Fiber-Tx Signal Fail)
The corresponding SNMP name for this condition is “fiberConnOptFault”.
AIDTYPE Default
Severity
Probable Cause Suggested Corrective
Action
PTP MN The transmitted optical power
level of the fiber detection
signal is below the failure
threshold.
Replace the module
supporting the facility.
Table 185: FC-OPT-SF (Standing Condition)
830 FSP 3000R7 Maintenance and Troubleshooting Manual - Product Release 16.2 - Document Issue A