Standing Conditions
APRLMT (Power Reduction-Limit)
The corresponding SNMP name for this condition is
automaticPowerReductionForEyeSafety.
AIDTYPE Default
Severity
Probable Cause Suggested Corrective Action
OM MJ Fiber break
Far end equipment
failure.
Excessive fiber loss.
Improper equipment
connection or
equipment failure.
1 Repair network fiber break.
2 Replace failed module or plug.
3 Clean fiber connections.
Launching into a span with an amplifier.
At the local site:
4 Verify that the amplifier is installed,
provisioned and operating normally.
5 Verify that the OSCM is installed,
provisioned and operating normally.
6 Verify that the OSCM network output is
connected to the amplifier clientport input.
7 Verify that the correct network fiber is
connected to the amplifier network output.
8 If needed, correct any fibering issues.
At the next site (other end of the span):
9 Verify that the amplifier is installed,
provisioned and operating normally.
10 Verify that the OSCM is installed,
provisioned and operating normally.
11 Verify that the OSCM network output is
connected to the amplifier client port input.
12 Correct any installation, provisioning or
fibering issues.
13 Verify that the OSC arriving at the amplifier
network port is within the specified power
range.
14 If the OSC is outside the specified range, this
indicates the span exceeds the maximum
allowable length. Address the span loss or
length issue as needed.
Table 130: APRLMT (Standing Condition)