Standing Conditions
SF-CFM7 (CFM Fault-Level 7)
The corresponding SNMP name for this condition is “sfCfmLevel7L2”.
AIDTYPE Default
Severity
Probable Cause Suggested Corrective Action
ELAN,
ELINE
NR The MEP
associated with
the facility at level
7 has detected a
signal failure
condition.
This condition is informative and no
corrective action is required. Corrective
action will be taken in response to
whatever condition(s) report the more
fundamental facility or equipment failure
which leads to this condition.
Table 382: SF-CFM7 (Standing Condition)
SF-LINK (Link-Signal Failure)
The corresponding SNMP name for this condition is “signalFailureOnLink”.
AIDTYPE Default
Severity
Probable
Cause
Suggested Corrective Action
CH NR The network
side signal
supporting the
virtual facility
reporting this
condition has
failed.
This condition is informative and no
corrective action is needed. Corrective
action will be taken in response to the signal
failure condition reported upstream. SF-
LINK is applicable to 4TCA4G-PCN-
4GU+4G and 4TCA4G-PCN-4GUS+4G
modules.
Table 383: SF-LINK (Standing Condition)
968 FSP 3000R7 Maintenance and Troubleshooting Manual - Product Release 16.2 - Document Issue A