Standing Conditions
APR (Power Reduction-Auto)
The corresponding SNMP name for this condition is “automaticPowerReduction”.
AIDTYPE Default
Severity
Probable Cause Suggested Corrective
Action
OM MN Fiber break.
The optical output
power has been
reduced to comply
with laser safety
limits.
This condition is informative
and requires no corrective
action. Corrective action
needs to be taken in response
to the reported signal failure.
Table 129: APR (Standing Condition)