Transient Conditions
SPEQ-WAIT (Span-Process Busy)
AIDTYPE Probable Cause Suggested Corrective Action
SPEQ A request to perform
span equalization
adjustment has been
denied since a prior
adjustment operation
is still in progress.
Await the completion of the request already in
progress and review the status to determine if
a subsequent request is necessary, and if so,
submit a new request at that time.
Table 617: SPEQ-WAIT (Transient Condition)
SPGAIN-AUTO (Span-Auto Gain
Adjust)
AIDTYPE Probable Cause Suggested Corrective
Action
SPEQ A loss of signal condition has cleared,
causing the automatic span equalization
process to re-assess the required gain
equalization settings affecting the optical
line.
This condition is
informative and no
corrective action is
needed.
Table 618: SPGAIN-AUTO (Transient Condition)
SPGAIN-DYNAMIC (Span-Dynamic
GainAdjust)
AIDTYPE Probable Cause Suggested
Corrective Action
SPEQ The optical power level of the received signal
at the amplifier has changed by an amount
sufficient to cause the automatic span
equalization process to re-assess the
required gain equalization settings affecting
the optical line.
This condition is
informative and no
corrective action is
needed.
Table 619: SPGAIN-DYNAMIC (Transient Condition)