Standing Conditions
MEA-DIFFER (Plug-Provision
Mismatch)
The corresponding SNMP name for this condition is “equipmentMismatch.
AIDTYPE Default
Severity
Probable Cause Suggested
Corrective Action
PL CR The physically inserted plug exceeds
the provisioned RATE or REACH
settings. Note that in this case, the
plug may be able to provide signal
transport, but the specifications of the
signal may not conform to the
provisioned settings (e.g. the optical
power level may be too high).
Review the
provisioning
attributes
associated with the
plug position and
replace the
unacceptable plug
with one of the
required type.
Table 284: MEA-DIFFER (Standing Condition)
MEA-FC-TX (Fiber-Connect Error Tx)
The corresponding SNMP name for this condition is “fiberConnMismatchTx”.
AIDTYPE Default
Severity
Probable Cause Suggested Corrective Action
PTP NR The port associated
with this fiber
connection has
determined that it
does not match the
connections
provisioned within
the system’s
database.
Note: This condition is normally not
reported, and corrective actions are
typically performed in response to the
MEA-FC (Fiber-Connect Error)
condition, which is reported by the
module at the opposite end of the
fiber.
1 Carefully trace the fiber to the far-
end port and determine to which
port the fiber is connected.
Review the intended fiber
connection provisioning plan and
adjust the fiber connections at
either or both ends so that they
conform to the plan, or correct the
connection provisioning if it is
found to be in error.
2 Replace the module at the far-end
of the fiber. If the condition still
fails to clear, replace the module
supporting the facility.
Table 285: MEA-FC-TX (Standing Condition)