Standing Conditions
SSF (Server Signal Fail)
The corresponding SNMP names for this condition can be
“cfmServerSignalFailure”, “serverSignalFail” or “serverSignalFailL2”.
AIDTYPE Default
Severity
Probable Cause Suggested Corrective Action
DOWN-MEP,
ELAN,
ELINE,
ELINE-PPP,
ETREE, LAG
NR An upstream
facility has failed,
causing a loss of
the server layer
signal.
This condition is informative and no
corrective action is needed.
Corrective action will be taken in
response to the signal failure reported
upstream.
Table 405: SSF (Standing Condition)
SSF-DCN (DCN-Server Signal Fail)
The corresponding SNMP name for this condition is “dcnServerSignalFailure”.
AIDTYPE Default
Severity
Probable Cause Suggested Corrective Action
DCN: {LIFIP|
LIFTENUM|
LIFTEUNN|
LIFVTENUM
LIFVTEUNN}
NR An upstream
facility has failed,
causing a loss of
the DCN signal.
This condition is informative and
no corrective action is needed.
Corrective action will be taken in
response to the signal failure
reported upstream.
Table 406: SSF-DCN (Standing Condition)
SSF-GFP (GFP-Server Signal Fail)
The corresponding SNMP name for this condition is “serverSignalFailureGfp”.
AIDTYPE Default
Severity
Probable Cause Suggested Corrective Action
CH: {1GBE |
FC | 2GFC }
NR An upstream facility
has failed, causing a
loss of the GFP
mapped signal.
This condition is informative and no
corrective action is needed.
Corrective action will be taken in
response to the signal failure
reported upstream.
CH: GFPT
Table 407: SSF-GFP (Standing Condition)
FSP 3000R7 Maintenance and Troubleshooting Manual - Product Release 16.2 - Document Issue A 985