Adva FSP 3000R7 - PWRNOAVAIL (Insufficient Power); PWRNOAVAIL (Standing Condition); PWRPROTNA (PSU-Not Protected); PWRPROTNA (Standing Condition)

Adva FSP 3000R7
1134 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Standing Conditions
PWRNOAVAIL (Insufficient Power)
The corresponding SNMP name for this condition is “insufficientPower”.
AIDTYPE Default
Severity
Probable Cause Suggested Corrective Action
SHELF MJ The equipment
consumes the
power supplied
by the power
units.
1 Verify that the power units are
provisioned and operational.
2 Verify that the shelf power
redundancy is provisioned
correctly.
3 If possible, install and provision
another power unit.
4 Remove and delete the last
provisioned module.
Table 353: PWRNOAVAIL (Standing Condition)
PWRPROTNA (PSU-Not Protected)
The corresponding SNMP name for this condition is “powerMissing”.
AIDTYPE Default
Severity
Probable Cause Suggested Corrective
Action
SHELF MN One of the two power
supply modules in a master
shelf is either not yet
provisioned or is
provisioned but not
equipped.
Ensure that both of the power
supply modules are correctly
provisioned and that both units
are properly equipped with
operational modules.
Table 354: PWRPROTNA (Standing Condition)
950 FSP 3000R7 Maintenance and Troubleshooting Manual - Product Release 16.2 - Document Issue A