Standing Conditions
NORP (Partner-No Response)
The corresponding SNMP name for this condition is “backupNotResponding”.
AIDTYPE Default
Severity
Probable Cause Suggested Corrective Action
MOD MJ
1
The backup
(standby) controller
in a duplex
protected pair is
not responding to
inter-module
communications.
1 Verify that the provisioning and
equipping of both members of the
duplex protection group is correct,
and that the backup module is not
reporting a failure. Correct any
provisioning or equipping errors, and
resolve any failure conditions
reported with respect to the backup
module.
2 Remove the inactive, standby
module. If this condition clears, and
is replaced by an indication that the
standby unit was removed, reseat
the standby module. If the original
condition recurs, replace the
standby module.
3 If the condition does not clear,
replace the shelf containing the
network controller modules.
Table 297: NORP (Standing Condition)
1
For NCU-II-P modules, the default severity is MN.
FSP 3000R7 Maintenance and Troubleshooting Manual - Product Release 16.2 - Document Issue A 907