Standing Conditions
VOACTRL_FAIL (Attenuator-Control
Fail)
The corresponding SNMP name for this condition is “voaControlFail”.
AIDTYPE Default
Severity
Probable Cause Suggested Corrective Action
CH MJ The optical power
on the output port
of the attenuator
module is unable
to be controlled.
1 Verify that the incoming cable is the
correct cable and that the receive
port is properly connected to the
intended source.
2 Verify that the attenuator
provisioning settings are correct and
adjust them as necessary.
3 Verify that the optical signal received
is within the specified operating
limits.
4 Replace the module.
Table 522: VOACTRL_FAIL (Standing Condition)
VOLTANR (Voltage Out of Range)
The corresponding SNMP name for this condition is “voltageOutOfRange.
AIDTYPE Default
Severity
Probable
Cause
Suggested Corrective Action
MOD MN At least one of
the internal
power supplies
(derived from the
incoming shelf
power) does not
work within the
normal operating
range.
1 Verify that the main supply
feeding the associated power
supply units is operating within
specifications.
2 Verify that the power supply
modules have not failed, and that
the shelf is equipped in a manner
consistent with the engineering
guidelines for power consumption
given the power supply modules
used within the shelf.
3 If multiple modules/plugs within
the same shelf report this
condition, replace the associated
power supply units.
4 If only one module/plug in the
shelf reports this condition,
replace the module.
Table 523: VOLTANR (Standing Condition)
FSP 3000R7 Maintenance and Troubleshooting Manual - Product Release 16.2 - Document Issue A 1069