Transient Conditions
T-SES-ODU-HT__1DAY (ODU-SES
Day)
AIDTYPE Probable Cause Suggested Corrective Action
CH The number of
severely errored
seconds measured
in the Optical Data
Unit (ODU) layer
exceeds the
provisioned 1-Day
threshold value.
This condition is informative and requires no
immediate corrective action. If the condition
persists across multiple intervals, it may indicate a
failure at the source or receiving plug or module, or a
failure in one of the cables along the path between
the source and the receiver.
To ensure that the condition is reported only under
the correct circumstances, verify that the 1-Day
threshold level is provisioned correctly.
Table 660: T-SES-ODU-HT__1DAY (Transient Condition)
T-SES-OTU-HT__1DAY (OTU-SES
Day)
AIDTYPE Probable Cause Suggested Corrective Action
CH The number of
severely errored
seconds measured
in the Optical
Transport Unit
(OTU) layer
exceeds the
provisioned 1-Day
threshold value.
This condition is informative and requires no
immediate corrective action. If the condition
persists across multiple intervals, it may indicate a
failure at the source or receiving plug or module, or a
failure in one of the cables along the path between
the source and the receiver.
To ensure that the condition is reported only under
the correct circumstances, verify that the 1-Day
threshold level is provisioned correctly.
Table 661: T-SES-OTU-HT __1DAY (Transient Condition)
1122 FSP 3000R7 Maintenance and Troubleshooting Manual - Product Release 16.2 - Document Issue A