Standing Conditions
LKDO-AIS-ODU-RCV (ODU-Auto
Shutdown Rx AIS)
The corresponding SNMP name for this condition is “oduAutoShutdownRxAIS”.
AIDTYPE Default
Severity
Probable Cause Suggested Corrective
Action
CH
VCH
VCHn
NR The receive direction signal
has been replaced with an
ODU Alarm Indication
Signal (AIS), due to a locally
detected or upstream failure
affecting the ODU path layer
signal. The replacement
signal is transmitted
towards the Rx of the cross
connection.
This condition is informative
and requires no corrective
action.
Corrective action will be taken
in response to the failure
condition reported locally or
upstream.
Table 223: LKDO-AIS-ODU-RCV (Standing Condition)
LKDO-AIS-ODU-TRMT (ODU-Auto
Shutdown Tx AIS)
The corresponding SNMP name for this condition is “oduAutoShutdownTxAIS”.
AIDTYPE Default
Severity
Probable Cause Suggested Corrective
Action
CH
VCH
VCHn
NR The transmit direction signal
has been replaced with an
ODU Alarm Indication
Signal (AIS) due to a locally
detected or upstream failure
affecting the ODU path layer
signal.
This condition is informative
and requires no corrective
action.
Corrective action will be taken
in response to the failure
condition reported locally or
upstream.
Table 224: LKDO-AIS-ODU-TRMT (Standing Condition)