Adva FSP 3000R7 - LOCAL_FAULT-TX (Local Fault Tx); LOCLANR (Rx Laser-Abnormal)

Adva FSP 3000R7
1134 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Standing Conditions
LOCAL_FAULT-TX (Local Fault Tx)
The corresponding SNMP name for this condition is “localFaultTx.
AIDTYPE Default
Severity
Probable
Cause
Suggested Corrective Action
CH NA The
upstream
equipment
has reported
a local fault.
The fault is
on the
module or the
plug.
1 Check the upstream equipment for a
local fault. If needed, take corrective
action in response to the signal failure
reported upstream.
2 Replace the module or plug.
Table 248: LOCAL_FAULT-TX (Standing Condition)
LOCLANR (Rx Laser-Abnormal)
The corresponding SNMP name for this condition is “localOscLevelAbnormal”.
AIDTYPE Default
Severity
Probable Cause Suggested Corrective Action
CH MN The drive current,
required to obtain the
desired optical signal
output power level
from a laser used for
the facility coherent
signal detection, is
abnormally high given
the present operating
conditions.
This likely means that the laser is
aging and is approaching its end-of-
life point, at which time the laser will
fail resulting in a traffic affecting
condition for the facility.
Replace the plug or module
supporting the facility, as
appropriate, during the next available
scheduled maintenance window.
Table 249: LOCLANR (Standing Condition)