Standing Conditions
RDI (RDI)
The corresponding SNMP name for this condition is “cfmRemoteDefectIndication”.
AIDTYPE Default
Severity
Probable Cause Suggested
Corrective Action
DOWN-
MEP
NR The incoming signal carries a
persistent Remote Defect Indication
(RDI), indicating that the signal in the
opposite direction has failed prior to its
termination point.
This condition is
informative and no
corrective action is
needed.
Table 356: RDI (Standing Condition)
RDI-L (Line/MS-Remote Defect)
The corresponding SNMP name for this condition is “remoteDefectIndicationLine”.
AIDTYPE Default
Severity
Probable Cause Suggested
Corrective Action
CH NR The incoming signal carries a persistent
Remote Defect Indication (RDI, also
known as Far-End Receive Failure or
FERF) indicating that the Line/Multiplex
Section signal in the opposite direction
has failed prior to its termination point.
This condition is
informative and no
corrective action is
needed.
Table 357: RDI-L (Standing Condition)
RDI-LP (Path LO-Remote Defect)
The corresponding SNMP name for this condition is
“remoteDefectIndicationLowerOrderPath”.
AIDTYPE Default
Severity
Probable Cause Suggested
Corrective Action
VC3 NR The incoming path carries a persistent
Remote Defect Indication (RDI, also
known as Far-End Receive Failure or
FERF) indicating that the path signal in
the opposite direction has failed prior to
its termination point.
This condition is
informative and no
corrective action is
needed.
Table 358: RDI-LP (Standing Condition)