Standing Conditions
MANSW (Manual Switch)
The corresponding SNMP name for this condition is “mansw.
AIDTYPE Default
Severity
Probable Cause Suggested Corrective Action
CH NA A manual protection
switch operation
has been performed
and the traffic is
switched to the
protecting member
of the protection
group.
This condition is informative and no
corrective action is needed.
Note
: This condition is reported only for
protection groups operating in a
revertive manner. In non-revertive
configurations, the transient conditions
MANWKSWPR (Manual
SwitchToProtect) and WKSWBK (Auto
SwitchToWorking) are issued for
changes in protection state due to
manual switching operations.
ETH A manual protection
switch operation
has been performed
and the traffic is
switched to the
protecting member
of the protection
group.
This condition is informative and no
corrective action is needed.
Note
: This condition is reported for all
flow protection groups regardless of
whether or not they are operating in a
revertive manner. The transient
conditions MANWKSWPR (Manual
SwitchToProtect) and MANWKSWBK
(Manual SwitchToWorking) are also
issued for changes in flow protection
group protection state due to manual
switching operations, regardless of
whether the group is operating in
revertive or non-revertive mode.
Table 275: MANSW (Standing Condition)
MEA-ACCEPT (Plug-Incompatible)
The corresponding SNMP name for this condition is “equipmentNotAccepted.
AIDTYPE Default
Severity
Probable Cause Suggested Corrective Action
PL CR The physically inserted
plug is of a type other
than that which is
provisioned.
Review the provisioning
attributes associated with the
plug and replace the
unacceptable plug with one of
the required type.
Table 276: MEA-ACCEPT (Standing Condition)