Standing Conditions
APS-PROT (Protection ProtocolFail)
The corresponding SNMP name for this condition is “apsProtocolFailure.
AIDTYPE Default
Severity
Probable Cause Suggested Corrective
Action
CH MN A protection switching
byte failure has been
detected (the received
code is either
inconsistent from frame
to frame or contains an
invalid value).
A channel mismatch
condition has been
detected (the channel
number received does
not match the channel
number transmitted).
Verify the provisioned
attributes (APS-TYPE,
TYPE, MECH, DIRN,
RVRTV) of the protection
groups at both the near and
far ends supporting the
facility reporting this
condition are set to equal
values.
Table 132: APS-PROT (Standing Condition)