Transient Conditions
RVSN-UNKNOWN (Reversion
Unknown)
AIDTYPE Probable Cause Suggested Corrective Action
WDM Tunnel No information is
available on
readiness to revert.
The control plane is
unable to detect
failed link repair and
hence will not
provide information
on reversion state.
This condition is informative and requires no
corrective action. Corrective action, if needed,
will be taken in response to an active failure
condition reported along the normal working
connection.
Table 610: RVSN-UNKNOWN (Transient Condition)
RVSN-WTR (Wait-to-Revert)
AIDTYPE Probable Cause Suggested Corrective
Action
WDM
Tunnel
The failure of the working connection has
been cleared, and the service has entered
the wait to restore hold-off time, after
which, the traffic will revert from the
protection connection back to the normal
working connection, assuming no failures
or other protection state causing changes
occur.
This condition is informative
and no corrective action is
needed.
Table 611: RVSN-WTR (Transient Condition)
SF-COM (Communication Fail)
AIDTYPE Probable Cause Suggested Corrective Action
OM The OPPM received
validated notification(s)
from its protection trigger
partner(s) that a signal
failure condition exists in
the network.
1 Refer to the alarm list to locate the
signal failure condition(s) raised by the
OPPM's protection trigger partner(s).
2 Follow the troubleshooting steps
indicated in this chapter to resolve the
alarm(s).
Table 612: SF-COM (Transient Condition)