Standing Conditions
T-ES-ODU-HT__15MIN (ODU-ES 15M)
The corresponding SNMP name for this condition is “thres15MinExceededOduES”.
AIDTYPE Default
Severity
Probable
Cause
Suggested Corrective Action
CH MN The number of
errored seconds
measured in the
Optical Data Unit
(ODU) layer
exceeds the
provisioned 15-
minute threshold
value.
This condition is informative and no
immediate corrective action is required. If
the condition persists across multiple
intervals, it may indicate an imminent
failure of a more serious nature, including
failure of either the source or receiving
plug or module or a failure in one of the
cables along the path between the source
and the receiver.
To ensure that the condition is reported
only under the correct circumstances,
verify that the 15-minute threshold level is
provisioned correctly.
Table 445: T-ES-ODU-HT__15MIN (Standing Condition)
T-ES-OTU-HT__15MIN (OTU-ES 15M)
The corresponding SNMP name for this condition is “thres15MinExceededOduES”.
AIDTYPE Default
Severity
Probable
Cause
Suggested Corrective Action
CH MN The number of
errored
seconds
measured in
the Optical
Transport Unit
(OTU) layer
exceeds the
provisioned 15-
minute
threshold
value.
This condition is informative and no
immediate corrective action is required. If
the condition persists across multiple
intervals, it may indicate an imminent failure
of a more serious nature, including failure of
either the source or receiving plug or module
or a failure in one of the cables along the
path between the source and the receiver.
To ensure that the condition is reported only
under the correct circumstances, verify that
the 15-minute threshold level is provisioned
correctly.
Table 446: T-ES-OTU-HT__15MIN (Standing Condition)