Standing Conditions
CHARSYNC-FEND (FEND Loss of Char
Sync)
The corresponding SNMP name for this condition is “lossOfCharSyncFromFarEnd”.
AIDTYPE Default
Severity
Probable Cause Suggested
Corrective Action
CH:
{F1062 |
F1250 }
NR The far-end has indicated that it has
encountered a loss of character
synchronization error in the signal
transmitted from this facility.
This condition is
informative and no
corrective action is
needed, since
corrective action
will be initiated by
the failure detected
at the far-end.
CH:
{GFPF |
GFPT }
The far-end has indicated that it has
encountered a loss of character
synchronization error in the received
client signal being mapped at that
point, and therefore the incoming
GFP signal contains a condition
code instead of an actual client
payload.
Table 155: CHARSYNC-FEND (Standing Condition)
CRY (Encryption-Disabled)
The corresponding SNMP name for this condition is
“encryptionPortEncryptionSwitchedOff”.
AIDTYPE Default
Severity
Probable
Cause
Suggested Corrective Action
MOD NA The
cryptographic
officer has
temporarily
disabled
encryption
functions.
This condition is informative and no
corrective action is needed. Cryptographic
functions are typically disabled temporarily
during installation and recovery tests. If not
manually re-enabled, encrypted operations
will automatically resume after a period of
time.
Table 156: CRY (Standing Condition)
810 FSP 3000R7 Maintenance and Troubleshooting Manual - Product Release 16.2 - Document Issue A