172 Chapter 4
Basic Digital Operation
Using Customized Burst Shape Curves
Generating the Waveform
Perform the following keypress sequence required for your format type.
For Custom Format
Press
Return > Custom Off On.
For TMDA Formats
Press
Return > Return > More (2 of 2) > desired format Off On.
This generates the custom modulation or TDMA state with user-defined burst shape created in the previous
sections. During waveform generation, the CUSTOM (or appropriate TDMA) annunciator and I/Q
annunciator activate. The waveform is now modulating the RF carrier.
Configuring the RF Output
1. Set the RF output frequency to 800 MHz.
2. Set the output amplitude to 10 dBm.
3. Press
RF On/Off.
The current real-time I/Q baseband digital modulation format with user-defined burst shape is now available
at the signal generators RF OUTPUT connector.