Chapter 14 397
Real Time TDMA Formats
Enhanced Observed Time Difference (E-OTD)
Sample SCPI Command Scripts
This section has two scenarios in which SCPI commands are used to setup the ESG to transmit a Broadcast
Channel (BCH).
Example 1, Setting Up a Non-Combined Broadcast Channel
This example will setup the ESG to generate a Non-Combined Broadcast Channel at 935.2 MHz with a
power level of –10 dBm. A public land mobile network (PLMN) value of 2 will be chosen and a base station
colour code (BCC) value of 3 will be set. The trigger will be setup in “trigger and run” mode which means
that the ESG will start generating a BCH on receipt of the first trigger and any further triggers will be
ignored. The trigger will be setup to use the external pattern trigger 1.
Reset the ESG to its power on state.
*RST
Select the frequency band, channel and power.
:FREQuency:CHANnels:BAND BPGSm
:FREQuency:CHANnels:NUMBer 1
:FREQuency:CHANnels:STATe ON
:POWer:LEVel:IMMediate:AMPLitude -10dBm
:RADio:GSM:BURSt:STATe ON
:RADio:GSM:SLOT0:NORMal:ENCRyption BCH1
:RADio:GSM:SLOT1:DUMMy:TSEQuence #H1C5C5C5
:RADio:GSM:SLOT2:NORMal:ENCRyption PN9
:RADio:GSM:SLOT3:NORMal:ENCRyption PN9
:RADio:GSM:SLOT4:NORMal:ENCRyption PN9
:RADio:GSM:SLOT5:NORMal:ENCRyption PN9
:RADio:GSM:SLOT6:NORMal:ENCRyption PN9
:RADio:GSM:SLOT7:NORMal:ENCRyption PN9
:RADio:GSM:SLOT0:TYPe NORMal
:RADio:GSM:SLOT1:TYPe DUMMy
:RADio:GSM:SLOT2:TYPe NORMal
:RADio:GSM:SLOT3:TYPe NORMal
:RADio:GSM:SLOT4:TYPe NORMal
:RADio:GSM:SLOT5:TYPe NORMal
:RADio:GSM:SLOT6:TYPe NORMal
:RADio:GSM:SLOT7:TYPe NORMal

Table of Contents

Other manuals for Agilent Technologies E4438C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies E4438C and is the answer not in the manual?

Agilent Technologies E4438C Specifications

General IconGeneral
BrandAgilent Technologies
ModelE4438C
CategoryPortable Generator
LanguageEnglish

Related product manuals