CHAPTER 6 EXPANDED EMERGENCY AND ABNORMAL PROCEDURES
EFD1000/500 MFD Pilot’s Guide
Page 6-2 091-00006-001 REV B
EFD1000/500 MFD Pilot’s Guide
Page 6-3091-00006-001 REV B
6.3. Abnormal Shutdown Procedure
In the event of an EFD malfunction requiring in-ight shut down of the equipment,
proceed as follows
Abnormal Shutdown Procedure
EFD1000 MFD (with EBB)
1. EFD Circuit Breaker / Switch ............................OFF / PULL
2. EBB Disconnect Switch.......................................DISC
OR -
EFD1000/500 display with internal battery
1. EFD Circuit Breaker / Switch ............................OFF / PULL
2. REV Button .................................................................PUSH AND HOLD UNTIL DISPLAY
BLANKS (Figure 6-1)
Figure 6-1
Powering O the
EFD1000/500 MFD
NOTE
Each EFD1000/500 has a dedicated circuit breaker
and master switch or combined circuit breaker switch.
These switches are mounted on or adjacent to the
instrument panel and within the pilot’s reach. The
switches are arranged left-to-right or top-to-bottom to
match the left-to-right orientation of the EFDs in the
panel.