User's Manual 764 Document #: LTRT-12809
Mediant 800 MSBR
Parameter Description
Web: Deny Authentication
Timer
EMS: WEB Deny
Authentication Timer
[DenyAuthenticationTim
er]
Defines the duration (in seconds) for which login to the Web interface
is denied from a specific IP address (for all users) when the number of
failed login attempts has exceeded the maximum. This maximum is
defined by the DenyAccessOnFailCount parameter. Only after this time
expires can users attempt to login from this same IP address.
The valid value is 0 to 100000, where 0 means that login is not denied
regardless of number of failed login attempts. The default is 60.
Web: Display Login
Information
[DisplayLoginInformatio
n]
Enables display of user's login information on each successful login
attempt.
[0] = Disable (default)
[1] = Enable
[EnableMgmtTwoFactor
Authentication]
Enables Web login authentication using a third-party, smart card.
[0] = Disable (default)
[1] = Enable
When enabled, the device retrieves the Web user’s login username
from the smart card, which is automatically displayed (read-only) in the
Web Login screen; the user is then required to provide only the login
password.
Typically, a TLS connection is established between the smart card and
the device’s Web interface, and a RADIUS server is implemented to
authenticate the password with the username. Thus, this feature
implements a two-factor authentication - what the user has (the
physical card) and what the user knows (i.e., the login password).
EMS: HTTPS Port
CLI: http-port
[HTTPport]
Defines the LAN HTTP port for Web management (default is 80). To
enable Web management from the LAN, configure the desired port.
Note: For this parameter to take effect, a device reset is required.
EMS: Disable WEB
Config
[DisableWebConfig]
Determines whether the entire Web interface is read-only.
[0] = (Default) Enables modifications of parameters.
[1] = Web interface is read-only.
When in read-
only mode, parameters can't be modified. In addition, the
following pages can't be accessed: 'Web User Accounts', 'Certificates',
'Regional Settings', 'Maintenance Actions' and all file-loading pages
('Load Auxiliary Files', 'Software Upgrade Wizard', and 'Configuration
File').
Notes:
For this parameter to take effect, a device reset is required.
[ResetWebPassword]
Resets the username and password of the primary ("Admin") and
secondary ("User") accounts to their default settings ("Admin" and
"Admin" respectively), and deletes all other users that may have been
configured.
[0] = (Default) Password and username retain their values.
[1] = Password and username are reset.
Notes:
For this parameter to take effect, a device reset is required.
You cannot reset the username and password through the Web
interface (by loading an ini file or on the AdminPage). To reset the
username and password, use SNMP:
a. Set acSysGenericINILine to WEBPasswordControlViaSNMP =
1, and reset the device with a flash burn (set