Parameter Description
the Progress message is received after a SIP REFER.
This parameter is applicable only if the parameter
SendISDNTransferOnConnect is set to 1.
Web: MFC R2 Category
EMS: R2 Category
CLI: mfcr2-category
[R2Category]
Defines the tone for MFC R2 calling party category (CPC). The
parameter provides information on the calling party such as
National or International call, Operator or Subscriber and
Subscriber priority.
The value range is 1 to 15 (defining one of the MFC R2 tones).
The default is 1.
Tone Index Table
Web: Tone Index Table
EMS: Analog Gateway
Provisioning > Tone Index
CLI: configure voip > gw
analoggw tone-index
[ToneIndex]
This table parameter configures the Tone Index table, which
allows you to define distinctive ringing and call waiting tones per
FXS endpoint (or for a range of FXS endpoints).
The format of this parameter is as follows:
[ToneIndex]
FORMAT ToneIndex_Index = ToneIndex_FXSPort_First,
ToneIndex_FXSPort_Last, ToneIndex_SourcePrefix,
ToneIndex_DestinationPrefix, ToneIndex_PriorityIndex;
[\ToneIndex]
For example, the configuration below plays the tone Index #3 to
FXS ports 1 and 2 if the source number prefix of the received call
is 20.
ToneIndex 1 = 1, 2, 20*, , 3;
Note:
For a detailed description of this table, see Configuring FXS
Distinctive Ringing and Call Waiting Tones per
Source/Destination Number.
66.11.9.2 Tone Detection Parameters
The signal tone detection parameters are described in the table below.
Tone Detection Parameters
Parameter Description
EMS: DTMF Enable
CLI: DTMF-detector-enable
[DTMFDetectorEnable]
Enables the detection of DTMF signaling.
[0] = Disable
[1] = Enable (default)
EMS: MF R1 Enable
CLI: MFR1-detector-enable
[MFR1DetectorEnable]
Enables the detection of MF-R1 signaling.
[0] = Disable (default)
[1] = Enable
EMS: R1.5 Detection Standard
[R1DetectionStandard]
Determines the MF-R1 protocol used for detection.
[0] = ITU (default)
[1] = R1.5
Note: For this parameter to take effect, a device reset is required.
EMS: User Defined Tone
Enable
CLI: user-defined-tones-
detector-enable
[UserDefinedToneDetectorE
nable]
Enables the detection of User Defined Tones signaling, applicable
for Special Information Tone (SIT) detection.
[0] = Disable (default)
[1] = Enable