The value must be an integer. The default is -1.
Web: MAX Incoming ANI Digits
[CASStateMachineMaxNumO
fIncomingANIDigits]
Defines the limitation for the maximum ANI digits that need to be
collected. After reaching this number of digits, the collection of
ANI digits is stopped.
The value must be an integer. The default is -1.
Web: Collect ANI
[CASStateMachineCollectAN
I]
In some cases, when the state machine handles the ANI
collection (not related to MFCR2), you can enable the state
machine to collect ANI or discard ANI.
[0] No = Don't collect ANI.
[1] Yes = Collect ANI.
[-1] Default = Default value.
Web: Digit Signaling System
[CASStateMachineDigitSigna
lingSystem]
Defines which Signaling System to use in both directions
(detection\generation).
[0] DTMF = DTMF signaling.
[1] MF = (Default) MF signaling.
[-1] Default = Default value.
66.11.6.4 ISDN Parameters
The ISDN parameters are described in the table below.
ISDN Parameters
Parameter Description
Web: ISDN Termination Side
EMS: Termination Side
CLI: isdn-termination-side
[TerminationSide]
Determines the ISDN termination side.
[0] User side = (Default) ISDN User Termination Equipment
(TE) side.
[1] Network side = ISDN Network Termination (NT) side.
Note: Select 'User side' when the PSTN or PBX side is
configured as 'Network side' and vice versa. If you don't know the
device's ISDN termination side, choose 'User side'. If the D-
channel alarm is indicated, choose 'Network Side'.
The BRI module supports the ITU-T I.430 standard, which defines
the ISDN-BRI layer 1 specification. The BRI and PRI ports are
configured similarly, using this parameter. When an NT port is
active, it drives a 38-V line and sends an INFO1 signal (as
defined in ITU-T I.430 Table 4) on the data line to synchronize to
a TE port that might be connected to it. To stop the voltage and
the INFO1 signal on the line, stop the trunk using the Stop Trunk
button.
[TerminationSide_x]
Same as the description for parameter TerminationSide, but for a
specific trunk ID (where x denotes the Trunk ID and 0 is the first
Trunk).
BRI Layer 2 Mode
CLI: isdn-layer2-mode
[BriLayer2Mode]
Determines whether Point-to-Point or Point-to-Multipoint mode for
BRI ports.
[0] Point to Point (default)
[1] Point to Multipoint = Must be configured for Network side.