User's Manual 770 Document #: LTRT-12809
Mediant 800 MSBR
Parameter Description
Web: Protocol
CLI: protocol
[TR069Protocol]
Defines the protocol used for the TR-069 connection.
[0] HTTP (default)
[1] HTTPS
Web: Port
CLI: port
[TR069HTTPPort]
Defines the local HTTP/S port used for TR-069.
The valid range is 0 to 65535. The default is 82.
Note: For this parameter to take effect, a device reset is required.
Web: User Name
CLI: acs-user-name
[TR069AcsUsername]
Defines the login username that the device uses for authenticated
access to the ACS.
The valid value is a string of up to 256 characters. By default, no
username is defined.
Web: Password
CLI: acs-password
[TR069AcsPassword]
Defines the login password that the device uses for authenticated
access to the ACS.
The valid value is a string of up to 256 characters. By default, no
password is defined.
Web: URL
CLI: connection-request-
url
[TR069ConnectionRequ
estUrl
Defines the URL for the ACS connection request. For example,
http://10.31.4.115:82/tr069/.
Web: User Name
CLI: connection-request-
user-name
[TR069ConnectionRequ
estUsername]
Defines the connection request username used by the ACS to connect
to the device.
The valid value is a string of up to 256 characters. By default, no
username is defined.
Web: Password
CLI: connection-request-
password
[TR069ConnectionRequ
estPassword]
Defines the connection request password used by the ACS to connect
to the device.
The valid value is a string of up to 256 characters. By default, no
password is defined.
Web: Inform Interval
CLI: inform-interval
[TR069PeriodicInformInt
erval]
Defines the inform interval (in seconds) at which the device periodically
communicates with the ACS. Each time the device communicates with
the ACS, the ACS sends a response indicating whether or not the ACS
has an action to execute on the device.
The valid value is 0 to 4294967295. The default is 60.
[TR069RetryinimumWait
Interval]
Defines the minimum interval (in seconds) that the device waits before
attempting again to communicate with the ACS after the previous
communication attempt failure.
The valid value is 1 to 65535. The default is 5.
CLI: debug-mode
[TR069DebugMode]
Defines the debug mode level, which is the type of messages sent to
the Syslog server.
The valid value is between 0 and 3, where 0 (default) means no debug
messages are sent and 3 is all message types are sent.